ملخص البحث :
policy.Close this notification
Skip to content
IOP Science home
Accessibility Help
IOP Conference Series: Materials Science and Engineering
PAPER • THE FOLLOWING ARTICLE ISOPEN ACCESS
Study of Electro-Fenton Oxidation for the Removal of oil content in refinery wastewater
Idrees Hammoody Ahmed1, Ali A. Hassan2 and Hussein Kareem Sultan2
Published under licence by IOP Publishing Ltd
IOP Conference Series: Materials Science and Engineering, Volume 1090, 1st International Conference on Engineering Science and Technology (ICEST 2020) 23rd-24th December 2020, Samawah, Iraq
Citation Idrees Hammoody Ahmed et al 2021 IOP Conf. Ser.: Mater. Sci. Eng. 1090 012005
DOI 10.1088/1757-899X/1090/1/012005
DownloadArticle PDF
183 Total downloads
1111 total citations on Dimensions.
Turn on MathJax
Share this article
Share this content via email
Share on Facebook (opens new window)
Share on Twitter (opens new window)
Share on Mendeley (opens new window)
Article and author information
Abstract
In this study, refinery wastewater treatment scheme, the electro-Fenton oxidation process is obtainable. Through Fenton oxidation treatment, numerous working limits remained examined, for instance hydrogen peroxide, electrolysis time and pH. The effects of the working variables including the pH (2-9), hydrogen peroxide concentration (20-60 mg/L) and the reaction time (10-30 minutes) and remained thoughtful through means of answer surface methodology and Minitab-17. The current, agitation speed and sodium chloride of the aqueous solution consumed remained engaged as 1 Amps, 200 rpm and 0.2 g congruently. Beneath the finest standards of the employed variables extra than 98% oil removal in refinery wastewater
-
سنة النشر : 2021
-
تصنيف البحث : scopus
- تحميل